This page (revision-29) was last changed on 26-Nov-2021 10:22 by jmyers

This page was created on 26-Nov-2021 10:22 by UnknownAuthor

Only authorized users are allowed to rename pages.

Only authorized users are allowed to delete pages.

Page revision history

Version Date Modified Size Author Changes ... Change note
29 26-Nov-2021 10:22 4 KB jmyers to previous 1ST_DAY_OF_WEEK ==> 1ST_DAY_OF_WEEK(System_Preference)
28 26-Nov-2021 10:22 4 KB JMyers to previous | to last
27 26-Nov-2021 10:22 4 KB JMyers to previous | to last
26 26-Nov-2021 10:22 4 KB Bill Hughes to previous | to last
25 26-Nov-2021 10:22 4 KB Bill Hughes to previous | to last
24 26-Nov-2021 10:22 4 KB Bill Hughes to previous | to last
23 26-Nov-2021 10:22 4 KB Bill Hughes to previous | to last
22 26-Nov-2021 10:22 4 KB JMyers to previous | to last
21 26-Nov-2021 10:22 4 KB JMyers to previous | to last

Page References

Incoming links Outgoing links

Version management

Difference between version and

At line 1 changed one line
!!Daily Device Clock Punches (DTDP)
[{TableOfContents }]
At line 3 changed one line
This function gives managers the ability to see who punched IN/OUT (clock entries) and from what clock device [ITCD] - (''Define Clock Devices'') they came from. //Most time clock implementations will have more than one clock device (time clock or punch clock); this calendar based screen allows managers to select a clock device and see by day who used the device to clock In/Out Device clock punches. //This functions allows a user to view the daily clock entries (punches) by clock device. It provides information a manager might want to see such as costing or shift information.
!!!DAILY DEVICE CLOCK PUNCHES (DTDP)
At line 5 changed 3 lines
Tables Accessed
P2K_TS_CLOCK_DEVICES
P2K_TS_CLOCK_ENTRIES
This function gives managers the ability to see who punched IN/OUT (clock entries) and from what clock device [ITCD] - (''Define Clock Devices'') they came from.\\ \\
Most time clock implementations will have more than one clock device (time clock or punch clock); this calendar based screen allows managers to select a clock device and see clock entries by day and by employee. It also provides information a manager might want to see such as costing or shift information.
At line 9 changed one line
Fields
The definition data for the Daily Device Clock Punches screen is stored in the [P2K_TS_CLOCK_DEVICES] and [P2K_TS_CLOCK_ENTRIES] tables.
At line 11 changed one line
Find by
!Calendar
Dynamic Calendars are used in the [DTSH] form to allow companies to specify the start of the work week. \\ In the [Preference tab of IMST|IMST#PreferencesTab], clients must add [1ST_DAY_OF_WEEK(System_Preference)] preference with a value of 1 through 7 where 1 represents Sunday and 7 represents Saturday.\\ \\The clock entry information below the calendar is derived based on the date in focus on the calendar.
At line 13 removed one line
Users can find clocks devices by the following:
At line 15 removed 2 lines
Clock Device
This is the user-defined code that uniquely identifies the clock device.
At line 18 changed 2 lines
Description (Clock Device)
This field allows the user to give additional information and description about the clock device.
!Clock Entry/Punch Details
At line 21 changed 2 lines
Description (Location)
This field holds a short description of the location (IDLN) of the clock device.
Clock entries can be viewed and adjusted through the [ITCE] function.
At line 24 changed one line
Calendar Date (Week view)
The following clock entry details can be seen by day based on the date in focus on the calendar above:
At line 26 changed 3 lines
Dynamic Calendars are used in the DTSH form to allow companies to specify the start of the work week.
In IMST in the preference tab clients must add 1ST_DAY_OF_WEEK preference; with a value of 1 thru 7; 1 representing Sunday to 7 representing Saturday.
The clock entry information below the calendar is derived based on the date in focus on the calendar.
!Time Entry
At line 30 changed one line
Clock Entry/Punch Details
;[Employee|EMPLOYEE]:This field displays the employee who created the clock entry.
At line 32 changed one line
Clock entries can be viewed and adjusted through the ITCE function.
;[Original Time|ORIGINAL_CLOCK_TIME]:This field displays the time of the original clock entry that came from the clock device.
At line 34 changed one line
The following clock entry details can be seen by day based on the date in focus on the calendar:
;[Type|CLOCK_ENTRY_TYPE]:This field identifies the type of clock entry being made. e.g. In, Out, Break, Lunch or Undetermined.
At line 36 changed one line
Time Entries
;[Adjusted Time|ADJUSTED_CLOCK_TIME]:If the clock has a rounding rule associated with the entries, and the highlighted entry has the rounding rule applied to it, that adjusted time will be shown here. For instance, if the rounding rule takes the clock in time to the next 5 minute mark, and they employee has punched in at 9:03, the time displayed as ‘adjusted time’ will be 9:05.
At line 38 changed 2 lines
Employee
This field displays the employee who created the clock entry.
!Costing Information
;[Time Code|TIME_CODE]:This field indicates the time code for this entry.
;[Job|JOB_CODE]:This field identifies the job and unit associated with the employee for this card entry.
;[Department|DEPARTMENT_CODE]:This field identifies the department associated with the employee for this card entry.
;[Cost Center|COST_CENTER_CODE]:This field identifies the cost center associated with the employee for this card entry.
;[Distribution Mask|DISTRIBUTION_MASK]:This field identifies the distribution code to receive part of all of the costs.
;[Reference Information|REFERENCE_INFORMATION]:This field will allow the user to include any additional information about the time entry. This field may be used to indicate the clock device if the G1 or G2 interface is used. Each time clock would be given a machine name that corresponds to a clock device ([ITCD]) in Personality. This code would be stored in the reference information for each clock entry.
%%information The following areas are view only%%
!Associated Scheduled Shift
At line 41 changed 2 lines
Original Time
This field displays the time of the original clock entry that came from the clock device.
;[Time Exception Type|TIME_EXCEPTION_TYPE]: The time exception type is used to record the type of exceptions to the schedule.
At line 44 changed 2 lines
Type
This field identifies the type of clock entry being made, e.g. In, Out, Break, Lunch or Undetermined.
;[Shift|SHIFT_CODE]: The scheduled shift displays in this field for the highlighted day.
At line 47 changed 2 lines
Adjusted Time
If the clock has a rounding rule associated with the entries, and the highlighted entry has the rounding rule applied to it, that adjusted time will be shown here. For instance, if the rounding rule takes the clock in time to the next 5 minute mark, and they employee has punched in at 9:03, the time displayed as ‘adjusted time’ will be 9:05.
;[Override Start Time|OVERRIDE_SHIFT_START_TIME]: If the shift start time has been overridden, the new time will be displayed here. Shift Start Time overrides typically take place on [DTSH] or [DTESH]
At line 50 changed one line
Costing Information
;[Override End Time|OVERRIDE_SHIFT_END_TIME]:If the shift end time has been overridden, the new time will be displayed here.
At line 52 changed one line
Time Code
;[Job/Unit|JOB_CODE]:This field identifies the job and unit associated with the employee for this card entry.
At line 54 changed one line
Job
!Clocking Details
;[Clock Entry Status|CLOCK_ENTRY_STATUS]:This field displays the status of the card entry. e.g. Newly Entered or Processed.
At line 56 changed one line
Department
;[Time Exception Status|TIME_EXCEPTION_STATUS]:This field displays the status of the time exception. e.g. Newly Entered or Processed.
At line 58 changed one line
Cost Center
;[Start Time|START_TIME]: This field holds the actual start time that will be used in time calculations; either the [Original Time|ORIGINAL_CLOCK_TIME] (In) will be used or if there have been rounding rules applied, the [Adjusted Time|ADJUSTED_CLOCK_TIME] (In) will be used instead.
At line 60 changed one line
Distribution Mask
;[End Time|END_TIME]: This field holds the actual end time that will be used in time calculations; either the [Original Time|ORIGINAL_CLOCK_TIME] (Out) or if there have been rounding rules applied, the [Adjusted Time|ADJUSTED_CLOCK_TIME] (Out) will be used instead.
At line 62 removed one line
Reference Information
At line 64 changed one line
Associated Scheduled Shift
----
At line 66 changed 21 lines
Time Exception Type
Shift
O/R Shift Start Time
O/R Shift End Time
Department
Job / Unit
Actual
Clock Entry Status
Time Exception Status
Start Time
End Time
![Notes|Edit:Internal.DTDP]
[{InsertPage page='Internal.DTDP' default='Click to create a new notes page'}]