This page (revision-29) was last changed on 26-Nov-2021 10:22 by jmyers

This page was created on 26-Nov-2021 10:22 by UnknownAuthor

Only authorized users are allowed to rename pages.

Only authorized users are allowed to delete pages.

Page revision history

Version Date Modified Size Author Changes ... Change note
29 26-Nov-2021 10:22 4 KB jmyers to previous 1ST_DAY_OF_WEEK ==> 1ST_DAY_OF_WEEK(System_Preference)
28 26-Nov-2021 10:22 4 KB JMyers to previous | to last
27 26-Nov-2021 10:22 4 KB JMyers to previous | to last
26 26-Nov-2021 10:22 4 KB Bill Hughes to previous | to last
25 26-Nov-2021 10:22 4 KB Bill Hughes to previous | to last
24 26-Nov-2021 10:22 4 KB Bill Hughes to previous | to last
23 26-Nov-2021 10:22 4 KB Bill Hughes to previous | to last
22 26-Nov-2021 10:22 4 KB JMyers to previous | to last
21 26-Nov-2021 10:22 4 KB JMyers to previous | to last

Page References

Incoming links Outgoing links

Version management

Difference between version and

At line 1 changed one line
[{TableOfContents }]
!!!Daily Device Clock Punches (DTDP)
At line 3 changed one line
!!!DAILY DEVICE CLOCK PUNCHES (DTDP)
This function gives managers the ability to see who punched IN/OUT (clock entries) and from what clock device [ITCD] - (''Define Clock Devices'') they came from. \\\Most time clock implementations will have more than one clock device (time clock or punch clock); this calendar based screen allows managers to select a clock device and see clock entries by day and by employee. It also provides information a manager might want to see such as costing or shift information.
At line 5 changed 2 lines
This function gives managers the ability to see who punched IN/OUT (clock entries) and from what clock device [ITCD] - (''Define Clock Devices'') they came from.\\ \\
Most time clock implementations will have more than one clock device (time clock or punch clock); this calendar based screen allows managers to select a clock device and see clock entries by day and by employee. It also provides information a manager might want to see such as costing or shift information.
!!Tables Accessed
[P2K_TS_CLOCK_DEVICES]\\
[P2K_TS_CLOCK_ENTRIES]\\
At line 8 changed one line
The definition data for the Daily Device Clock Punches screen is stored in the [P2K_TS_CLOCK_DEVICES] and [P2K_TS_CLOCK_ENTRIES] tables.
!!Fields on the screen
At line 10 changed 2 lines
!Calendar
Dynamic Calendars are used in the [DTSH] form to allow companies to specify the start of the work week. \\ In the [Preference tab of IMST|IMST#PreferencesTab], clients must add [1ST_DAY_OF_WEEK(System_Preference)] preference with a value of 1 through 7 where 1 represents Sunday and 7 represents Saturday.\\ \\The clock entry information below the calendar is derived based on the date in focus on the calendar.
!Find by
At line 13 added one line
Users can find clocks devices by the following:
At line 15 added one line
;[Clock Device|CLOCK_DEVICE_CODE]:This is the user-defined code that uniquely identifies the clock device.
At line 17 added 7 lines
;[Description (Clock Device)|DESCRIPTION]:This field allows the user to give additional information and description about the clock device.
;[Description (Location)|DESCRIPTION]:This field holds a short description of the location ([IDLN]) of the clock device.
!Calendar
Dynamic Calendars are used in the DTSH form to allow companies to specify the start of the work week. \\ In [IMST] in the preference tab clients must add [1ST_DAY_OF_WEEK] preference; with a value of 1 thru 7; 1 representing Sunday to 7 representing Saturday. \\The clock entry information below the calendar is derived based on the date in focus on the calendar.
At line 19 changed one line
The following clock entry details can be seen by day based on the date in focus on the calendar above:
The following clock entry details can be seen by day based on the date in focus on the calendar:
At line 21 changed one line
!Time Entry
;[Time Entries|TIME_ENTERED]:
At line 27 changed one line
;[Type|CLOCK_ENTRY_TYPE]:This field identifies the type of clock entry being made. e.g. In, Out, Break, Lunch or Undetermined.
;[Type|CLOCK_ENTRY_TYPE]:This field identifies the type of clock entry being made, e.g. In, Out, Break, Lunch or Undetermined.
At line 37 changed 2 lines
;[Reference Information|REFERENCE_INFORMATION]:This field will allow the user to include any additional information about the time entry. This field may be used to indicate the clock device if the G1 or G2 interface is used. Each time clock would be given a machine name that corresponds to a clock device ([ITCD]) in Personality. This code would be stored in the reference information for each clock entry.
%%information The following areas are view only%%
;[Reference Information|REFERENCE_INFORMATION]:This field will allow the user to include any additional information about the time entry. This field may be used to indicate the clock device if the G1 or G2 interface is used. Each time clock would be given a Machine Name that corresponds to a clock device ([ITCD]) in [{$applicationname}]. This code would be stored in the reference information for each clock entry.
At line 41 changed one line
;[Time Exception Type|TIME_EXCEPTION_TYPE]: The time exception type is used to record the type of exceptions to the schedule.
Time Exception Type
At line 43 changed one line
;[Shift|SHIFT_CODE]: The scheduled shift displays in this field for the highlighted day.
Shift
At line 45 changed one line
;[Override Start Time|OVERRIDE_SHIFT_START_TIME]: If the shift start time has been overridden, the new time will be displayed here. Shift Start Time overrides typically take place on [DTSH] or [DTESH]
O/R Shift Start Time
At line 47 changed one line
;[Override End Time|OVERRIDE_SHIFT_END_TIME]:If the shift end time has been overridden, the new time will be displayed here.
O/R Shift End Time
At line 49 changed one line
;[Job/Unit|JOB_CODE]:This field identifies the job and unit associated with the employee for this card entry.
Department
At line 51 changed 2 lines
!Clocking Details
;[Clock Entry Status|CLOCK_ENTRY_STATUS]:This field displays the status of the card entry. e.g. Newly Entered or Processed.
Job / Unit
At line 54 changed one line
;[Time Exception Status|TIME_EXCEPTION_STATUS]:This field displays the status of the time exception. e.g. Newly Entered or Processed.
Actual
At line 56 changed one line
;[Start Time|START_TIME]: This field holds the actual start time that will be used in time calculations; either the [Original Time|ORIGINAL_CLOCK_TIME] (In) will be used or if there have been rounding rules applied, the [Adjusted Time|ADJUSTED_CLOCK_TIME] (In) will be used instead.
Clock Entry Status
At line 58 changed one line
;[End Time|END_TIME]: This field holds the actual end time that will be used in time calculations; either the [Original Time|ORIGINAL_CLOCK_TIME] (Out) or if there have been rounding rules applied, the [Adjusted Time|ADJUSTED_CLOCK_TIME] (Out) will be used instead.
Time Exception Status
At line 68 added one line
Start Time
At line 61 changed 4 lines
----
![Notes|Edit:Internal.DTDP]
[{InsertPage page='Internal.DTDP' default='Click to create a new notes page'}]
End Time