!!!TR_OUT_SE_BK - Clock OUT Backward in Time !!Time Rule Overview Clocking OUT for Shift End adjust Backward in time This time rule identifies when an employee clocks OUT for the end of a shift and adjusts the clock time to the nearest value, in minute intervals, backward in time. This time rule is applied during the processing of a raw clock punch, such as an [ITCE] process punch action. !!Additional Info * Frequency predefined as Never !!Implementation The time rule should be set up in IDWR as shown below. ||[Cycle|CYCLE_NUMBER]||[Frequency|FREQUENCY]||[Seq|SEQUENCE]||[Time Rule Type|TIME_RULE_TYPE_TEXT]||[Band|QUALIFYING_BAND]||[From|FROM_CLOCK_TIME]||[To|TO_CLOCK_TIME]||[Value|VALUE]||[Day|DAY_OF_WEEK]||[Time Code|TIME_CODE_VALUE]||[Premium|PREMIUM_CODE]||[Target Time Code Set|TARGET_TIME_CODE_SET]|| [Apply Time Code Set|APPLY_TIME_CODE_SET]||[Action|TIME_RULE_ACTION] | |Never|-3| |No|No|No|Required. Interval to round to, in minutes|No|No|No|No|No|Replace [1] [1] The adjusted time replaces the original Clock Time in ITCE.