!!!TR_IN_SS_FWD - Clock IN Early Time Forward to Shift Start
!!Time Rule Overview
This time rule identifies when an employee clocks IN EARLY before a shift start time and adjusts the time:

* Forward to the Shift Start time, if clocking IN is less than the band time in minutes, otherwise 
* To the NEXT Value in time, in minute intervals, forward in time.

!!Requirements / Features
This time rule is applied during the processing of a clock punch, such as an ITCE process punch action.

!!Additional  Info 
* [Frequency|FREQUENCY] predefined as Never

* The time rule should be set up in [IDWR] as shown below

!!Implementation
||[Cycle|CYCLE_NUMBER]||[Frequency|FREQUENCY]||[Seq|SEQUENCE]||[Time Rule Type|TIME_RULE_TYPE_TEXT]||[Band|QUALIFYING_BAND]||[From|FROM_CLOCK_TIME]||[To|TO_CLOCK_TIME]||[Value|VALUE]||[Day|DAY_OF_WEEK]||[Time Code|TIME_CODE_VALUE]||[Premium|PREMIUM_CODE]||[Target Time Code Set|TARGET_TIME_CODE_SET]|| [Apply Time Code Set|APPLY_TIME_CODE_SET]||[Action|TIME_RULE_ACTION]
| |Never|-1| |Required. # of minutes before a shift, causing the adjusted time to be the Shift Start time |No|No|Required. Interval to round to, in minutes|No|No|No|No|No|Replace [1]

[1] Adjusted time replaces the original clock time, in ITCE


----
![Notes|Edit:Internal.TR_IN_LT_SS_FWD]
[{InsertPage page='Internal.TR_IN_SS_FWD' default='Click to create a new notes page'}]