!!Handle Accumulators !Functionality: These three functions manipulate internal numeric accumulators for controlling totalling and counting within the [UPPHF] and [UEEF] when something beyond that which is possible with these two programs is needed. There are 20 numeric accumulators provided for in this package. * P2K_PU.ACCUM_INIT will initialize the values of the accumulators to the number provided, or zero if not specified * P2K_PU.ACCUM_ADD will change the values of the accumulators by the number provided, or increment by 1 if not specified * P2K_PU.ACCUM_VALUE will retrieve the current value of the accumulator indicated !P2K_PU.ACCUM_INIT ||Parameters|| |Return | This is just a pass through value. Whatever is specified here will be returned back. This functionality allows for the initialization of accumulators in a field that is a constant value, with that value being passed back. |Accumulators| ''Optional.'' A number from 1 to 20 which indicates which accumulator you wish to set to a specified value. If not provided, all accumulators (1 through 20) will be set to the number provided. |Value | ''Optional.'' A number which represents the initialized value. If not provided, the accumulator(s) identified will be set to zero. Note: If you use any of the following functions without initializing the accumulators, you will always get NULL back. !P2K_PU.ACCUM_ADD ||Parameters|| |Return | This is just a pass through value. Whatever is specified here will be returned back. This functionality allows for the increment of accumulators without changing the interface value. |Accumulators| A number from 1 to 20 which indicates which accumulator you wish to change to a specified value. |Value | ''Optional.'' A number which represents the incremental value. If not provided, the accumulator identified will be incremented by one. !P2K_PU.ACCUM_ADD ||Parameters|| |Accumulators| A number from 1 to 20 which indicates which accumulator whose value you returned !Example: {{P2K_PU.ACCUM_INIT('HHS521')}} will set accumulators 1 through 20 to a zero value, and will return back the constant HHS521. {{P2K_PU.ACCUM_INIT('HHS521',3,2)}} will set only accumulator 3 to a value of 2, returning the constant value. {{P2K_PU.ACCUM_ADD('543123',3)}} will increase the value of accumulator 3 by one (default) and return the constant value 543123. {{P2K_PU.ACCUM_ADD('543123',3,-27)}} will reduce the value of accumulator 3 by 27 (subtract) and return the constant value. {{P2K_PU.ACCUM_VALUE(3)}} will return the current value of accumulator 3 ---- ![Notes|Edit:Internal.P2K_PU.ACCUMULATORS] [{InsertPage page='Internal.P2K_PU.ACCUMULATORS' default='Click to create a new notes page'}]